Activa 6G BS-VI Engine Audio Dataset: Healthy and Defective Samples 核心 · 已核验
doi:10.21227/4bew-ny52
"Engine condition monitoring traditionally relies oninvasive sensor diagnostics and periodic servicing. This paperpresents a comprehensive, non-invasive acoustic-based approachusing multiple advanced signal processing techniques to detectengine faults through frequency-domain, time-frequency-domain,and perceptual-domain analysis of real-time engine sound signals.Experimental validation is conducted on the Honda Activa 6GBS-VI compliant 109.51 cc air-cooled single-cylinder four-strokeengine. Beyond classical Fast Fourier Transform (FFT), weemploy Continuous Wavelet Transform (CWT), Mel-FrequencyCepstral Coefficients (MFCC), and Short-Time Fourier Trans-form (STFT)-based spectrogram analysis. Experimental valida-tion on twenty-seven audio samples (twenty-one healthy, sixdefective) from actual Activa 6G BS-VI engines reveals: (1) FFT-based spectral centroid classification achieves 100% accuracy;(2) spectral centroid elevation of 70% indicates high-frequencynoise dominance; (3) spectral flatness increases 124% in defectiveengines; (4) harmonic-to-noise ratio degrades 4.2 dB. Spectro-gram analysis reveals temporal fault evolution. The ensembleclassifier achieves 100% accuracy enabling specific fault typeidentification. This cost-effective, non-invasive framework enablesreal-time predictive maintenance"
- 落地页
- https://ieee-dataport.org/documents/activa-6g-bs-vi-engine-audio-dataset-healthy-and-defective-samples
- 许可证
- CC-BY-4.0 (判读置信:inferred)
- 国内可访问性
-
国内直连:可达 (2026-07-11 检测)
代理通道:可达 (2026-07-11 检测)
检测口径:lychee 双通道单轮探测;「直连超时」表示检测窗口内未完成,系慢或不稳定证据,不构成封锁证据。 - PHM 任务
condition_monitoringfault_detection
故障工况
| fault_type: healthy_baseline |
溯源(PROV,5 条)
| source_url: https://ieee-dataport.org/documents/activa-6g-bs-vi-engine-audio-dataset-healthy-and-defective-samplessource_citation: quarry_mining_pool datacite#10.21227/4bew-ny52retrieved_on: 2026-07-09asserted_by: automated_harvestnote: 反向挖掘 v3(KLS-018,词表圈选+全量人工复核):level=L2 score=0.75;候选区,晋升需人工核验 |
| about_field: fault_conditionssource_citation: graphrag 抽取自论文 doi:10.21227/4bew-ny52(model=glm-5.2, temperature=0)retrieved_on: 2026-07-10asserted_by: automated_extractionconfidence_level: grounded_nativenote: values: healthy_baseline;候选区,晋升需人工核验(ADR-26) |
| about_field: taskssource_citation: graphrag 抽取自论文 doi:10.21227/4bew-ny52(model=glm-5.2, temperature=0)retrieved_on: 2026-07-10asserted_by: automated_extractionconfidence_level: grounded_nativenote: values: condition_monitoring, fault_detection;候选区,晋升需人工核验(ADR-26) |
| about_field: source_citation: 人工核验:zfbin(委托批准 2026-07-10)retrieved_on: 2026-07-10asserted_by: human_curatorconfidence_level: human_verifiednote: 晋升核心区。晋升批次 05:KLS-018 挖掘池卡,逐卡逐断言对照自述核验(evidence/KLS-016/08) |
| about_field: china_accessibilitysource_citation: KLS-009 链接健康扫描(lychee 双通道)retrieved_on: 2026-07-11asserted_by: automated_harvestnote: 定期刷新标注,仅覆盖本字段;历史结果以最新扫描为准 |