Dataset of Fatigue Testing on Type III CFRP Composite Pressure Vessels Using a Hydraulic Impulse Test Stand 核心 · 已核验

doi:10.5281/zenodo.20035409

This dataset contains raw experimental data from cyclic pressure testing of commercially available Type III CFRP composite pressure vessels with an aluminum liner, conducted on a hydraulic impulse test stand. The investigated vessels feature a multi-layer fiber-reinforced overwrap (CFRP and GFRP) and were instrumented with strain gauges (axial – 0° and circumferential – 90°), a Type K thermocouple, and a pressure sensor to capture the structural response under cyclic loading.

Tests were performed in a pressure range between 5 and 45 MPa at a constant frequency of 5 Hz. All sensor signals were recorded at a sampling rate of 600 Hz without any post-processing or filtering, providing fully raw measurement data. To accommodate the test setup, the internal volume of the vessels was reduced using steel displacement bodies.

A total of eight experiments were conducted, resulting in fatigue lives between 22,678 and 41,295 cycles until failure. The vessels exhibited a consistent leak-before-break behavior, with failure detected by a pressure drop due to leakage. Post-test analysis revealed crack initiation in the aluminum liner as the primary failure mechanism, followed by progressive damage in the surrounding CFRP layers and local fluid permeation through the composite structure. No catastrophic fragmentation was observed.

The dataset provides high-resolution, multi-sensor time series data suitable for fatigue analysis, structural health monitoring, and validation of numerical models for composite pressure vessels under cyclic loading.

Overview

Test

Date

File

Cycles

Notes

1

13.01.2026

test_1

22678

2

14.01.2026

test_2

24423

3

15.01.2026

test_3

27434

Strain Gauge 2 has come loose

4

16.01.2026

test_4

27595

5

26.01.2026

test_5

27303

6

27.01.2026

test_6

34523

7

27.01.2026

test_7

41295

8

28.01.2026

test_8

32250

9

19.03.2026

test_9

25998

Stopped after 10000 cyles and restartet after cooling down

落地页
https://zenodo.org/doi/10.5281/zenodo.20035409
许可证
CC-BY-4.0 (判读置信:inferred)
国内可访问性
国内直连:直连超时(慢或不稳定,非封锁证据) (2026-07-11 检测) 代理通道:可达 (2026-07-11 检测)
检测口径:lychee 双通道单轮探测;「直连超时」表示检测窗口内未完成,系慢或不稳定证据,不构成封锁证据。
设备类型
composite_structure pressure_vessel
PHM 任务
health_state_assessment

故障工况

fault_type: fatigue_crack

传感器

sensor_type: strain_gauge
sensor_type: thermocouple
sensor_type: pressure_transducer

运行工况

condition_type: pressure
溯源(PROV,10 条)
source_url: https://zenodo.org/doi/10.5281/zenodo.20035409source_citation: quarry_mining_pool datacite#10.5281/zenodo.20035409retrieved_on: 2026-07-09asserted_by: automated_harvestnote: 反向挖掘 v3(KLS-018,词表圈选+全量人工复核):level=L2 score=1;候选区,晋升需人工核验
about_field: equipment_typessource_citation: graphrag 抽取自论文 doi:10.5281/zenodo.20035409(model=glm-5.2, temperature=0)retrieved_on: 2026-07-10asserted_by: automated_extractionconfidence_level: grounded_nativenote: values: hydraulic_system;候选区,晋升需人工核验(ADR-26)
about_field: fault_conditionssource_citation: graphrag 抽取自论文 doi:10.5281/zenodo.20035409(model=glm-5.2, temperature=0)retrieved_on: 2026-07-10asserted_by: automated_extractionconfidence_level: grounded_nativenote: values: fatigue_crack, seal_leakage;候选区,晋升需人工核验(ADR-26)
about_field: operating_conditionssource_citation: graphrag 抽取自论文 doi:10.5281/zenodo.20035409(model=glm-5.2, temperature=0)retrieved_on: 2026-07-10asserted_by: automated_extractionconfidence_level: grounded_nativenote: values: pressure;候选区,晋升需人工核验(ADR-26)
about_field: sensorssource_citation: graphrag 抽取自论文 doi:10.5281/zenodo.20035409(model=glm-5.2, temperature=0)retrieved_on: 2026-07-10asserted_by: automated_extractionconfidence_level: grounded_nativenote: values: strain_gauge, thermocouple, pressure_transducer;候选区,晋升需人工核验(ADR-26)
about_field: taskssource_citation: graphrag 抽取自论文 doi:10.5281/zenodo.20035409(model=glm-5.2, temperature=0)retrieved_on: 2026-07-10asserted_by: automated_extractionconfidence_level: grounded_nativenote: values: health_state_assessment;候选区,晋升需人工核验(ADR-26)
about_field: equipment_types,fault_conditionssource_citation: 人工核验:zfbin(委托批准 2026-07-10)retrieved_on: 2026-07-10asserted_by: human_curatorconfidence_level: human_verifiednote: 人工改写。核验剔除 equipment_types=hydraulic_system(液压为试验台激励,受试对象是复材压力容器)+ fault_conditions=seal_leakage(泄漏系内衬疲劳裂纹表现,非密封件故障)
about_field: source_citation: 人工核验:zfbin(委托批准 2026-07-10)retrieved_on: 2026-07-10asserted_by: human_curatorconfidence_level: human_verifiednote: 晋升核心区。晋升批次 05:KLS-018 挖掘池卡,逐卡逐断言对照自述核验(evidence/KLS-016/08)
about_field: equipment_typessource_citation: 人工核验:zfbin(词表修订拍板 2026-07-10)retrieved_on: 2026-07-10asserted_by: human_curatorconfidence_level: human_verifiednote: 人工改写。词表回填 equipment=composite_structure+pressure_vessel(Type III CFRP composite pressure vessels)
about_field: china_accessibilitysource_citation: KLS-009 链接健康扫描(lychee 双通道)retrieved_on: 2026-07-12asserted_by: automated_harvestnote: 定期刷新标注,仅覆盖本字段;历史结果以最新扫描为准