Photovoltaic Inverter Input Arc-Fault and Normal Operation Waveforms Dataset 核心 · 已核验

mxds4gdwf1xs3w07

"The dataset contains voltage and current waveforms measured at the input terminals of a photovoltaic (PV) inverter during controlled arc-fault experiments.The arcs were generated using a PV arc-fault generator powered by a solar battery through the inverter, and the corresponding signals were recorded using Tektronix DPO4034B oscilloscopes.The measurements were performed under laboratory conditions to simulate different arc behaviors and to support the development of machine-learning and signal-processing techniques for arc-fault detection in photovoltaic systems."

本卡描述如含来自官方页的原文片段,其版权归原作者,不在本站 CC-BY 4.0 许可范围(见关于与许可)。

落地页
https://ieee-dataport.org/documents/photovoltaic-inverter-input-arc-fault-and-normal-operation-waveforms-dataset-0
国内可访问性
国内直连:可达 (2026-07-11 检测) 非直连:可达 (2026-07-11 检测)
「直连超时」表示检测窗口内未完成,系慢或不稳定证据,不构成封锁证据。
设备类型
power_electronics_device
PHM 任务
fault_detection

故障工况

fault_type: healthy_baseline
溯源(9 条)
来源链接: https://ieee-dataport.org/documents/dataset-photovoltaic-inverter-input-arc-fault-and-normal-operation-waveforms-dataset 日期: 2026-07-09
日期: 2026-07-10
日期: 2026-07-10
日期: 2026-07-10
日期: 2026-07-10
日期: 2026-07-11
日期: 2026-07-11
日期: 2026-07-25
日期: 2026-07-29