Power Converter Fault Diagnosis Dataset 核心 · 已核验
mxds91rww96yht72
This dataset contains electrical measurements acquired from a real-time Hardware-in-the-Loop (HIL) simulation environment developed for fault diagnosis research in power electronic converters.
The simulated system corresponds to a 2 MW two-level voltage source inverter (2L-VSI) connected to a three-phase 400/690 V, 50 Hz electrical grid and a 1500 V DC bus. The model was executed on a Typhoon HIL606 real-time simulator, enabling the controlled injection of multiple fault conditions while preserving the dynamic behavior of the converter.
The dataset includes measurements collected under both nominal and faulty operating conditions. A total of 48 operating categories are represented, corresponding to one healthy operating mode and 47 fault conditions. The simulated faults include grid disturbances, DC-bus abnormalities, semiconductor failures, harmonic distortion, electrical noise, voltage deviations, frequency variations, phase-sequence alterations, short-circuits, and disconnection events.
To improve dataset diversity and reduce phase-dependent bias, fault injection was performed at randomly selected temporal instants during converter operation.
Included Measurements
This repository contains the following measurement categories:
id_mea = 10 — Three-Phase RMS Voltages
Three-dimensional measurement composed of the RMS values of the three grid voltages. This low-dimensional representation characterizes the global electrical operating condition of the converter and the grid.
Dimensions: 3
id_mea = 3 — Instantaneous DC Voltage and Current
High-dimensional instantaneous measurements containing the DC-link capacitor voltage and input current sampled at switching frequency. The resulting vectorized representation captures transient and dynamic behaviors associated with fault conditions.
Dimensions: 40
id_mea = 2 — Instantaneous Three-Phase Currents
High-dimensional vectorized representation of the three-phase grid currents sampled at switching frequency. The me
本卡描述如含来自官方页的原文片段,其版权归原作者,不在本站 CC-BY 4.0 许可范围(见关于与许可)。
- 落地页
- https://zenodo.org/doi/10.5281/zenodo.20484337
- 许可证
- CC-BY-4.0 (置信:verified_official)
- 国内可访问性
-
国内直连:直连超时(慢或不稳定,非封锁证据) (2026-07-11 检测)
非直连:可达 (2026-07-11 检测)
「直连超时」表示检测窗口内未完成,系慢或不稳定证据,不构成封锁证据。 - 发布年份
- 2026
- 发布方
- Zenodo
- 设备类型
power_electronics_device- PHM 任务
fault_diagnosis
故障工况
| fault_type: healthy_baseline |
| fault_type: power_electronics_fault |
关联论文(1 篇)
仅表示这篇论文与本数据集在文献网络中相邻, 不代表该论文确实使用了本数据集。
溯源(9 条)
| 来源链接: https://api.datacite.org/dois/10.5281/zenodo.20484337 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-12 |
| 日期: 2026-07-25 |
| 日期: 2026-07-26 |
| 日期: 2026-07-31 |