In-house PMSM Multi-Location Vibration Dataset for Fault Diagnosis under Physically Induced Disturbances 核心 · 已核验
mxdsax27c4qj9q33
Note: This dataset is provided as supplementary material for a manuscript currently under peer review. This dataset contains tri-axial vibration signals of a permanent magnet synchronous motor (PMSM) collected under various sensor locations and physically induced disturbance conditions. It is designed to evaluate the cross-location generalization and false alarm suppression capabilities of fault diagnosis models. [Experimental Setup] Motor: Frameless inrunner PMSM (CubeMars RI60 KV120) Operating Condition: 500 RPM, No-load condition Sensor: LSM6DS3TR-C (STMicroelectronics) tri-axial MEMS accelerometer Sampling Rate: 5 kHz Diagnostic Classes (5 states): Normal (NR), Bearing Fault (BF), Magnet Fault (MF), Stator Fault (SF), and Eccentricity Fault (EF). Recording Duration: 10 seconds per recording. Trials: 5 independent recordings were acquired for each diagnostic class under the specified conditions. Temporal Variability: To introduce realistic distribution shifts, data acquisition for each sensor location (Loc S, Loc A, Loc B, and Loc C) was conducted on different days (separated time intervals). This dataset contains permanent magnet synchronous motor (PMSM) vibration signals collected under various sensor locations and physically induced disturbance conditions. The dataset is structured into six subsets: [Dataset Structure] LocS_Train_Clean: Data measured at the reference location (Loc S, 12 o'clock) under clean conditions without any external physical disturbances. LocS_Train_Noise: Data measured at Loc S (12 o'clock) while applying five types of physically induced disturbances (D1-D5: vibration motor contact and hammer strikes). LocS_Val_Clean: An independent, held-out dataset measured under the same clean conditions at Loc S, strictly separated from the training set. LocC_Val_Test_Noise: Data measured after relocating the sensor to a new evaluation location (Loc C, 2 o'clock) with disturbances (D1-D5) applied. This subset was used for validation during model selection and also included in the final evaluation, so it should be interpreted as a validation-exposed location rather than a strictly unseen test location. LocA_Test_Noise: Data measured at an entirely new location (Loc A, 9 o'clock) with disturbances (D1-D5) applied. This subset represents a strictly unseen test location. LocB_Test_Noise: Data measured at another entirely new location (Loc B, 11 o'clock) with disturbances (D1-D5) applied. This subset also represents a strictly unseen test location.
本卡描述如含来自官方页的原文片段,其版权归原作者,不在本站 CC-BY 4.0 许可范围(见关于与许可)。
- 落地页
- https://zenodo.org/records/19717375
- 许可证
- CC-BY-4.0 (置信:verified_official)
- 国内可访问性
-
国内直连:直连超时(慢或不稳定,非封锁证据) (2026-07-11 检测)
非直连:可达 (2026-07-11 检测)
「直连超时」表示检测窗口内未完成,系慢或不稳定证据,不构成封锁证据。 - 设备类型
synchronous_motor- PHM 任务
fault_diagnosis
故障工况
| fault_type: healthy_baseline |
| description: 诊断类 BF,部位未述fault_type: bearing_fault_unspecified |
传感器
| sensor_type: accelerometer |
关联论文(2 篇)
仅表示这篇论文与本数据集在文献网络中相邻, 不代表该论文确实使用了本数据集。
溯源(13 条)
| 来源链接: https://zenodo.org/records/19717375 日期: 2026-07-09 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-12 |
| 日期: 2026-07-14 |
| 日期: 2026-07-25 |
| 日期: 2026-07-26 |