"CNC machine tool fault data" 核心 · 已核验
mxdshp8qmkcvdc37
"Experimental platform for milling-machine vibration acquisition.Experimental validation was conducted on a CNC milling machine (model: XK713CG-11) equipped with a triaxial piezoelectric accelerometer (model: DONGHUA 1A314E). Data were collected using a dynamic signal acquisition system (model: DH5922D) configured with a sampling rate of 50 kHz to ensure accurate capture of the transient dynamic characteristics inherent in the milling process, such as intermittent cutting, varying chip loads, and complex tool\u2013workpiece interactions. The experiments covered multiple fault conditions, including no-load operation, eccentricity, normal operation, shaft-center asymmetry (0.15-si copper shim at the bearing base), and bearing-seat looseness, in order to comprehensively characterize vibration patterns under different abnormal states."
本卡描述如含来自官方页的原文片段,其版权归原作者,不在本站 CC-BY 4.0 许可范围(见关于与许可)。
- 落地页
- https://ieee-dataport.org/documents/cnc-machine-tool-fault-data
- 国内可访问性
-
国内直连:可达 (2026-07-11 检测)
非直连:可达 (2026-07-11 检测)
「直连超时」表示检测窗口内未完成,系慢或不稳定证据,不构成封锁证据。 - 设备类型
machine_tool- PHM 任务
condition_monitoring
故障工况
| fault_type: healthy_baseline |
| fault_type: mechanical_looseness |
传感器
| sensor_type: accelerometer |
溯源(9 条)
| 来源链接: https://ieee-dataport.org/documents/cnc-machine-tool-fault-data 日期: 2026-07-09 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-11 |
| 日期: 2026-07-25 |
| 日期: 2026-07-29 |