SCADA dataset of a 2 MW SIEMENS wind turbine drivetrain located at a wind farm on the Baltic Sea coast in northern Poland 核心 · 已核验
mxdswj0c123y0h09
This dataset contains Supervisory Control and Data Acquisition (SCADA) measurements from a 2 MW Siemens wind turbine drivetrain located at a wind farm on the Baltic Sea coast in northern Poland. The data were extracted to investigate whether early indicators of a gearbox fault could be detected using data-driven analysis.
The monitoring period spans 30 days, from November 1, 2012 (00:00) to November 30, 2012 (23:50). Operational parameters were recorded at 10-minute intervals, resulting in 4,320 time-series samples for each parameter.
The dataset includes twelve process parameters describing the turbine’s operational condition, grouped into rotational dynamics, electrical power generation, and thermal conditions. Rotational parameters include wind speed, rotor speed, and generator speed. Electrical parameters include active power, generated power, reactive power, reactive power delivered, generator voltage, and generator current, representing the turbine’s power generation and load conditions. Thermal parameters include gearbox bearing temperature and two generator temperature sensors, indicating the thermal state of key components.
During operation, a gearbox bearing failure occurred and was recorded on November 9, 2012 at 13:00 (sample 1232). The dataset therefore contains both normal operational data and data preceding the fault event. In the related study, generator speed and gearbox bearing temperature were used to validate a stationarity-based anomaly detection method.
SCADA measurements represent 10-minute averaged values, typical for wind turbine monitoring systems. The dataset contains no missing or corrupted values, making it suitable for research on condition monitoring, anomaly detection, time-series analysis, and predictive maintenance of wind turbines.
Related published papers:
1) P.B. Dao, W.J. Staszewski, T. Barszcz, and T. Uhl, “Condition monitoring and fault detection in wind turbines based on cointegration analysis of SCADA data,” Renewable E
本卡描述如含来自官方页的原文片段,其版权归原作者,不在本站 CC-BY 4.0 许可范围(见关于与许可)。
- 落地页
- https://data.mendeley.com/datasets/3sys4562ny/1
- 许可证
- CC-BY-4.0 (置信:verified_official)
- 国内可访问性
-
国内直连:可达 (2026-07-11 检测)
非直连:可达 (2026-07-11 检测)
「直连超时」表示检测窗口内未完成,系慢或不稳定证据,不构成封锁证据。 - 发布年份
- 2026
- 发布方
- Mendeley Data
- 设备类型
wind_turbinegearboxrolling_bearing- PHM 任务
fault_detectionanomaly_detectioncondition_monitoring
运行工况
| condition_type: rotating_speed |
| condition_type: load |
溯源(15 条)
| 来源链接: https://api.datacite.org/dois/10.17632/3sys4562ny.1 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-10 |
| 日期: 2026-07-11 |
| 日期: 2026-07-25 |
| 日期: 2026-07-26 |
| 日期: 2026-07-31 |
| 引文: 「To reproduce the analysis, load the SCADA dataset recorded from November 1, 2012 to November 30, 2012 at 10-minute intervals. Use the average values of the 12 process parameters. No preprocessing is required, since the dataset contains no missing, corrupted, or unphysical values. For validation of the stationarity-based method, analyze in particular the generator speed and gearbox bearing temperature time series. The gearbox bearing failure occurred on November 9, 2012 at 13:00, corresponding to sample 1232.」 来源链接: https://data.mendeley.com/public-api/datasets/3sys4562ny 日期: 2026-09-02 |
| 来源链接: https://data.mendeley.com/public-api/datasets/3sys4562ny 日期: 2026-09-02 |
| 日期: 2026-09-02 |
| 日期: 2026-09-02 |
| 来源链接: https://data.mendeley.com/public-api/datasets/3sys4562ny 日期: 2026-09-02 |
| 日期: 2026-09-02 |